Samsung Dryers

Samsung DVE45T6000

Model # DVE45T6000

The DVE45T6000 is a 7.5 cu. ft. electric dryer, listed by Samsung as Front Load Electric Dryer | Sensor Dry | Smart Care | 7.5 cu.ft.. An electric dryer like the DVE45T6000 needs both legs of its 240-volt supply to heat, and a drum that turns with cold air is checked at the outlet and breaker before the heating element or its thermostats are suspected.

On the DVE45T6000 we treat dn as a firmware download in progress and CL as child lock, neither of which is a problem; the real codes – tS, tE, tC, dC, dE, 9C1, FC – are tested with the breaker off and the drum cool before anything is replaced.

Key Features

  • 7.5 cu. ft. drum capacity
  • Electric dryer
  • Sensor Dry moisture sensing
  • SmartThings Wi-Fi connection with cycle notifications
  • Also sold as DVE45T6000W - the same platform in brushed black, white

Most Common Issues on This Model

01

Igniter glowing without a flame

02

Drum turning with no heat

03

tS, tE or tC temperature sensor code

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

Book Your Repair Today

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 702-1398 now

FAQ

Samsung DVE45T6000 FAQ

Treat it as a measurement on the DVE45T6000: Samsung describes C80 as roughly eight-tenths blocked and C90 as more than nine-tenths. With the DVE45T6000 switched off and cool, clear the lint screen and its housing, then disconnect the transition hose behind the dryer and check the duct run and the outside hood for packed lint or a flap that will not open. Run the test again once the duct is clear.

On the DVE45T6000, HC, hE and HC4 are Samsung’s heating codes, and the usual cause is a clogged lint screen or exhaust rather than a failed part. With the DVE45T6000 unplugged and cool, clean the screen and check the vent first; if the code returns with a clear vent, the thermistor, the high-limit thermostat and the element or gas valve are what gets tested.

Need a repair? We're ready to help. Call Now
Call Us Schedule