Samsung Dryers

Samsung DVG55CG7100WA

Model # DVG55CG7100WA

The DVG55CG7100WA is a 7.4 cu. ft. gas dryer, listed by Samsung as Top Load Gas Dryer Steam Sanitize+ Sensor Dry | 7.4 cu.ft.. On a gas dryer like the DVG55CG7100WA, the igniter glows, the flame sensor opens the gas valve coils and the burner lights; a drum that turns with no heat is traced through those three parts in that order, with the gas supply confirmed shut at the appliance valve before the burner housing is opened.

On the DVG55CG7100WA we treat dn as a firmware download in progress and CL as child lock, neither of which is a problem; the real codes – tS, tE, tC, dC, dE, 9C1, FC – are tested with the breaker off and the drum cool before anything is replaced.

Key Features

  • 7.4 cu. ft. drum capacity
  • Gas dryer
  • Steam Sanitize+ cycle
  • Steam refresh cycle
  • Sensor Dry moisture sensing

Most Common Issues on This Model

01

tS, tE or tC temperature sensor code

02

Clg, C80 or C90 vent-test result

03

dC or dE door code with the door latched

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

Book Your Repair Today

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 702-1398 now

FAQ

Samsung DVG55CG7100WA FAQ

Treat it as a measurement on the DVG55CG7100WA: Samsung describes C80 as roughly eight-tenths blocked and C90 as more than nine-tenths. With the DVG55CG7100WA switched off and cool, clear the lint screen and its housing, then disconnect the transition hose behind the dryer and check the duct run and the outside hood for packed lint or a flap that will not open. Run the test again once the duct is clear.

On the DVG55CG7100WA, HC, hE and HC4 are Samsung’s heating codes, and the usual cause is a clogged lint screen or exhaust rather than a failed part. With the DVG55CG7100WA unplugged and cool, clean the screen and check the vent first; if the code returns with a clear vent, the thermistor, the high-limit thermostat and the element or gas valve are what gets tested.

Need a repair? We're ready to help. Call Now
Call Us Schedule